HMTA
This Static Converter further improves the relationship between quality, durability and price. Compact dimensions of the SERIE H with 3-stage architecture can drive lamps up to 12.0 kW and reach working voltages up to 2000 V.
The cooling of this Static Converter is guaranteed by an internal 24 VDC fan and therefore the absorption of the 24 VDC auxiliary power supply will be 2.5 A per converter. As a result, 220 V will no longer be needed to power the cooling fan.
| Main Voltage 220 Vac | |||||||
| STATIC CONVERTER MODEL |
Max Power | Max V Lamp | |||||
| kW | V | ||||||
| HMTA-18 | 4,0 | 1100 | |||||
| HMTA-25 | 5,5 | ||||||
| HMTA-30 | 6,6 | ||||||
| Main Voltage 400/480 Vac | |||||||
| STATIC CONVERTER MODEL |
Max Power | Max V Lamp | |||||
| kW | V | ||||||
| HMTA-18 | 7,2 | 2000 | |||||
| HMTA-25 | 10,0 | ||||||
| HMTA-30 | 12,0 | ||||||
| Mains Characteristic: | |||||||
| Machine Type | HMTA-18 | HMTA-25 | HMTA-30 | ||||
| Main Voltage +/- 5% | 200-510 Vac 3 Phase | ||||||
| Frequency | > 47 Hz | ||||||
| COS | 1 | ||||||
| Power Factor | 0.96 | ||||||
| THD | 30% (hex Bridge) | ||||||
| Efficiency | 94% | ||||||
| Output Section: | |||||||
| Working frequency | 400 Hz | ||||||
| Ignition Voltage | > 4000 V pp | ||||||
| Ignition Frequency | 270 KHz | ||||||
| Fan Air flow | 150 m3/h | 150 m3/h | 200 m3/h | ||||
| Auxiliary Section: | |||||||
| Machine Type | HMTA-18 | HMTA-25 | HMTA-30 | ||||
| Voltage | 21-30 Vdc | ||||||
| Current | 2.5 A | 2.5 A | 2.5 A | ||||
| Working Environment: | |||||||
| Machine Type | HMTA-18 | HMTA-25 | HMTA-30 | ||||
| Max Oprating Temp | 40 °C (up to 1000m Above See Level) | ||||||
| Max Humidity | 50% | ||||||
| Protection Class | IP 20 | ||||||